Tekmar 279 Steam Control Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Sensores Tekmar 279 Steam Control. tekmar 279 Steam Control User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
1 of 24 © 2010 D 279 - 05/10
D 279
05/10
- Data Brochure
Steam Control 279
The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The
control determines the on time of the boiler or valve based on the measured outdoor temperature and settings entered by
the installer. A large LCD displays the current status and operating temperatures.
Additional functions include:
CSA approved for use in USA and Canada
Outdoor Reset
Manual Override
Includes Outdoor Sensor
Includes Condensate Sensor
Large LCD Display
Optional Indoor Sensors
DHW Tankless Coil Operation
Warm Weather Shut Down
Built-in Programmable Timer
24 Hour, 5-1-1, 7 Day Schedule
Two or Four Schedule Events Per Day
Two Alert Level Relays
Input
Universal Sensor
Optional
Input
Indoor Sensor
Optional
Input
Universal Sensor
Included
Input
Outdoor
Sensor
Included
Output
Boiler or On/Off
Steam Valve
Input
115 V (ac)
Power Supply
OR
Input
Indoor Sensor
Optional
M
Output
High Priority
Alert
Output
Low Priority
Alert
DHW Tankless Coil Sensor
Condensate Sensor
Average
Indoor S2
Indoor S1
Alert 2
LowHigh
Steam Control 279
One Stage
Menu Item
Test
Power 115 V ±10% 50/60 Hz 3.5 VA
Relays 230 V (ac) 5 A 1/3 hp, pilot duty 240 VA
Made in Canada By
tekmar Control Systems Ltd.
tektra 969-04
For manual operation,
press and hold Test
button for 3 seconds.
not testing
testing
testing paused
off
red
red
User
Installer
Setback
Off
Date Code
H2046A
2
N
3
Alert 1 Boiler
4
Power
L
Indr
12
S2
DHW
11
Sen
Com
10
Sen
Com
9
Sen
Indr
13
S1
6785
Do not apply power
1
Out
Sen
16
Cdn
Sen
15
Com
Sen
14
STATUS
Establishing Steam
Heat Cycle
Lockout Differential
DHW Tankless Coil Heating
Meets Class B:
Canadian ICES
FCC Part 15
Signal wiring must be rated at least 300 V.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - - Data Brochure

1 of 24 © 2010 D 279 - 05/10D 27905/10- Data BrochureSteam Control 279The tekmar Steam Control 279 can operate a single on-off steam boiler or

Pagina 2 - User Interface

© 2010 D 279 - 05/10 10 of 24 Domestic Hot Water Tankless Coil Section NThe control can replace the mechanical aquastat in the steam boiler that

Pagina 3 - Menu Item

11 of 24 © 2010 D 279 - 05/10All electrical wiring terminates in the control base wiring chamber. The base has standard 7/8” (22 mm) knoc

Pagina 4 - Establishing Steam

© 2010 D 279 - 05/10 12 of 24 BoilerThe Boiler terminals (7 and 8) are isolated outputs in the control. There is no power available on these term

Pagina 5

13 of 24 © 2010 D 279 - 05/10In order to test the sensors, the actual temperature at each sensor location must be measured. A good qualit

Pagina 6

© 2010 D 279 - 05/10 14 of 24 Cleaning the ControlThe control’s exterior can be cleaned using a damp cloth. Moisten the cloth with water and wrin

Pagina 7

15 of 24 © 2010 D 279 - 05/10Switch SettingsGENERALThe switch settings on the control are very important and should be set to the appropr

Pagina 8 - Built-in Timer Section G

© 2010 D 279 - 05/10 16 of 24 Display MenusView Menu (1 of 1) Item Field RangeAccessDescription-76 to 149°F(-60.0 to 65.0°C)UserOUTDOOR SECTION

Pagina 9 - Occupied OccupiedUnoccupied

17 of 24 © 2010 D 279 - 05/10Item Field Range Access Description Actual Setting35 to 100°F (1.5 to 38.0°C) Default = 70°F (21.0°C)UserROO

Pagina 10 - Installation

© 2010 D 279 - 05/10 18 of 24 Item Field Range Access Description Actual Setting35 to 100°F (1.5 to 38.0°C) Default = 70°F (21.0°C)InstallerINDOO

Pagina 11 - Terminals 3 - 8

19 of 24 © 2010 D 279 - 05/10ADJUST MENUItem Field Range Access Description Actual Setting35 to 100°F (1.5 to 38.0°C) Default = 65°F (18.

Pagina 12 - Terminals 10 - 16

© 2010 D 279 - 05/10 2 of 24 How to Use the Data BrochureTable of Contents This brochure is organized into four main sections. They are: 1) Seque

Pagina 13

© 2010 D 279 - 05/10 20 of 24 Note: The Setback/Off switch setting must be in the Setback position in order to have access to the SCHEDULE menu.S

Pagina 14 - Cleaning the Control

21 of 24 © 2010 D 279 - 05/10Establish the problem. Get as much information from the customer as possible about the problem. Is there too

Pagina 15 - Switch Settings

© 2010 D 279 - 05/10 22 of 24 E01 MEMORY ERRORThe E01 memory error message causes the Alert 1 High relay to turn on.The control was unable to rea

Pagina 16 - VIEW MENU

23 of 24 © 2010 D 279 - 05/10Error Messages (2 of 2)ROOM 1 SHORT CIRCUITThe room 1 short circuit error message causes the Alert 2 Low rel

Pagina 17 - ADJUST MENU

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fa

Pagina 18

3 of 24 © 2010 D 279 - 05/10DisplayPOINTERDisplays the control operation as indicated by the text.°°F°C°F, °CUnits of measurement.OCCUPIE

Pagina 19

© 2010 D 279 - 05/10 4 of 24 Establishing Steam Section BSequence of OperationPowering up the controlWhen the control is powered on, all segment

Pagina 20 - Testing the Control

5 of 24 © 2010 D 279 - 05/10The Adjust menu includes a Steam Established setting that delays the start of the heating cycle until the con

Pagina 21 - Menu Item Menu Item Menu Item

© 2010 D 279 - 05/10 6 of 24 Heating Cycle - Heating Curve Section COutdoor reset is a method of operating a heating system based on the fact th

Pagina 22 - Error Messages (1 of 2)

7 of 24 © 2010 D 279 - 05/10Heating Cycle - Cycle Length Section DThe Adjust menu includes a setting called Cycle that determines how of

Pagina 23 - Error Messages (2 of 2)

© 2010 D 279 - 05/10 8 of 24 Optional Indoor Sensors Section FMultiple indoor sensors can be added to improve the temperature accuracy within th

Pagina 24 - Technical Data

9 of 24 © 2010 D 279 - 05/10Optimum Start Section JThe control includes an optimum start feature that is available in the Adjust menu wh

Comentarios a estos manuales

Sin comentarios