RTU View Menu
ItemMenu
UnOcc 1
°
F
View
Heat
The access level that is to be used by the control.
DIP switch =
Unlock
OFF, 30 sec, ON
Default = ON
ADV, INST, USER, LTD
Default = INST
The operating mode for the back lighting on the LCD as well
as the time of keypad inactivity until the control automatically
returns to the default display.
BACKLITE = OFF
(returns after 10 seconds)
BACKLITE = 30 sec (returns after 30 seconds)
BACKLITE = ON (returns after 90 seconds)
362 Misc (Miscellaneous) Menu (2 of 2)
LTD
INST
ADV
Range
Access
Level
DescriptionItem Field
USER
RTU
062
Current room air temperature.
RTU SENS = AIR
- - -, 14 to 167˚F
(-10 to 75˚C)
Target room air temperature.
RTU SENS = AIR
- - -, 35 to 100˚F
(2 to 38˚C)
Current outdoor air temperature.
-67 to 149˚F
(-55 to 65˚C)
Current slab (floor) sensor temperature.
REMOTE 3 = SLAB
-58 to 167˚F
(-50 to 75˚C)
RTU
063
••
362 RTU View Menu (1 of 1)
Section
LTD
INST
ADV
Range
Access
Level
DescriptionItem Field
USER
B2
B2
B2
Room Temperature Units (RTUs) 062 and 063
A single RTU may be connected to the Mixing Control 362 in order to provide the control with indoor
temperature feedback for the mixing side of the heating system (Refer to Essay E 002). When using
an RTU, several items related to the mixing side of the heating system are no longer available in the
controls User Interface. These items are available only in the RTUs User Interface. Also, the number
of items that are available on the RTU depends on the type of RTU that is connected to the control.